MicroMag 2900/3900 Data File (Series 0016.002)
Remanence curves:  DCD

INSTRUMENT
Configuration                   VSM
Temperature control             None
Hardware version                0004
Software version                01/29/2013
Units of measure                Hybrid SI
Temperature in                  Kelvin

SAMPLE
Mass                            N/A
Volume                          N/A
Demagnetizing factor            N/A

SETTINGS
Field range                     N/A
Field (command)                 N/A
Moment range                   +50.00000E-06
Averaging time                 +100.0000E-03
Temperature (command)           N/A
Tmprtr difference correction    No
Orientation                     0.000000E+00
Vibration amplitude             1.0
Calibration factor             +5.019859E+00
Operating frequency            +83.00000E+00

MEASUREMENT
Description                    ""
Field (measured)                N/A
Temperature (measured)          N/A
Averages (completed)            N/A
Measured on                     09/05/2023  09:59
Elapsed time                   +98.28086E+00

PROCESSING
Background subtraction          No
Delta-m processing              No
Demagnetizing factor            No
Normalization                   No
Normalization factor            N/A
Offset (field)                  No
Offset (moment)                 No
Pole saturation                 No
Slope correction                No

VIEWPORT
Left                           -100.0000E-03
Right                          +100.0000E-03
Bottom                         -50.00000E-06
Top                            +50.00000E-06
Show X-axis?                    Yes
Show Y-axis?                    Yes

CHARACTERIZATION
Initial slope                   N/A
Saturation                      N/A
Remanence                      +40.23329E-06
Coercivity (direct)             N/A
Coercivity (remanent)          +23.64098E-03
S* (direct)                     N/A
S* (DCD)                       +25.47884E-03

SCRIPT
Include IRM?                    No
Include DCD?                    Yes
Include direct moment?          No
Demagnetize before measuring?   No
Field sequence                  Nonlinear
Initial (non-zero) field       +10.00000E-06
Final field                    +100.0000E-03
Number of points/curve          30
Pause at applied field         +100.0000E-03
Slew rate to applied field     +1.000000E+00
Averaging time                 +100.0000E-03
Saturating field               +100.0000E-03
Pause at saturating field      +1.000000E+00
Saturating field applied        Only once
Slew rate to saturating field  +1.000000E+00
Pause at zero field            +100.0000E-03
Slew rate to zero field        +1.000000E+00
Number of segments              1
Number of data                  30

Segment   Averaging      Initial        Field         Final                    Final 
 Number      Time         Field       Increment       Field         Pause      Index 
             (s)           (T)           (T)           (T)           (s)     
0000001,+100.0000E-03, 0.000000E+00,+10.00000E-06,-100.0000E-03,+100.0000E-03,0000030

                           
    Field       Remanence  
     (T)          (Am)    
+604.8612E-09,+40.23329E-06
-10.44211E-06,+40.20773E-06
-23.74583E-06,+40.18448E-06
-41.46042E-06,+40.17071E-06
-63.05341E-06,+40.15321E-06
-93.72046E-06,+40.12035E-06
-134.4514E-06,+40.08426E-06
-187.0986E-06,+40.02252E-06
-257.1341E-06,+39.94255E-06
-349.0910E-06,+39.83116E-06
-471.2771E-06,+39.67719E-06
-631.7965E-06,+39.47989E-06
-844.8369E-06,+39.20844E-06
-1.126240E-03,+38.84610E-06
-1.498368E-03,+38.36406E-06
-1.988562E-03,+37.71348E-06
-2.637791E-03,+36.82886E-06
-3.490945E-03,+35.65055E-06
-4.623273E-03,+34.01549E-06
-6.116780E-03,+31.77068E-06
-8.097283E-03,+28.60807E-06
-10.71182E-03,+24.14035E-06
-14.15718E-03,+17.74151E-06
-18.71449E-03,+8.927900E-06
-24.73440E-03,-1.981509E-06
-32.69292E-03,-13.69297E-06
-43.20697E-03,-24.44718E-06
-57.09156E-03,-32.70444E-06
-75.41290E-03,-37.81892E-06
-99.69693E-03,-40.26545E-06

MicroMag 2900/3900 Data File ends